Natural Ventilation Strategy To Enhance Comfort In Traditional Bajo Tribe Houses : A Case Study In Lemo Bajo Village, Lembo District, North Konawe Regency

Authors

  • Mamang Roulus Universitas Muhammdiyah Kendari

DOI:

https://doi.org/10.51454/anoa.v3i01.1058

Keywords:

Natural Ventilation, Tradisioanl House, Bajo Tribe, Thermal Comfort, Vernacular Architecture

Abstract

This research examines natural ventilation strategies in traditional houses of the Bajo tribe in Lemo Bajo Village, Lembo District, North Konawe Regency. The study aims to identify and analyze natural ventilation patterns applied to traditional Bajo tribal houses and their impact on occupants’ thermal comfort. The research method uses qualitative and quantitative approaches with direct measurements of temperature, humidity, and wind speed at several points inside and outside the building. The results show that the natural ventilation design of Bajo tribal houses has unique characteristics formed from adaptation to the coastal climate. Proper opening applications, building orientation according to wind direction, and local materials contribute to creating a comfortable thermal environment. This research provides recommendations for developing more optimal natural ventilation designs in traditional Bajo tribal houses.

References

DAFTAR PUSTAKA

Amin, A. R. Z. (2018). Studi Penghawaan Alami Pada Bangunan Sekolah Dasar Di Pinggiran Sungai Musi Palembang. Arsir, 1(2), 86-99.

Aritama, A. A. N. (2023). Faktor-Faktor yang Berpengaruh terhadap Kenyamanan Termal Rumah Tradisional Desa Tenganan Pegringsingan. Jurnal Patra, 5(1), 28-36.

HELFIALNA, F. (2023). ANALISIS TINGKAT KENYAMANAN TERMAL DAN KEPUASAN PENGGUNA (Studi Kasus: Gedung Laboratorium Teknik Mesin Universitas Malikussaleh) (Doctoral dissertation, Universitas Malikussaleh).

Kusdiwanggo, S., & Yusran, Y. A. (2024). Systematic Literature Review (SLR): Keberlanjutan Arsitektur Tradisional dan Vernakular dalam Menghadapi Zaman pada Konteks Urban Rural. Jurnal Lingkungan Binaan Indonesia, 13(4), 190-200.

Kusumawardhani, S. (2024). Penerapan Prinsip Arsitektur Hijau pada Lumbung Padi Vernakular Kasepuhan Gelar Alam-Sukabumi, Indonesia: Warisan Kearifan Lokal yang Berkelanjutan. Waca Cipta Ruang, 10(2), 86-95.

Misbach, I. P., Bakri, M., & Sumarto, D. A. (2022). Konsep Optimalisasi Kenyamanan Termal Pada Perancangan Pusat Pelatihan Bahasa Asing di Banda Aceh. Jurnal Arsitektur ARCADE.

Nugroho, A. M. (2016). Keberlanjutan ruang binaan nusantara di wilayah pesisir. Jurnal Lingkungan Binaan Indonesia, 5(4), 177-181.

Nugroho, A. M., & Iyati, W. (2021). Arsitektur Bioklimatik: Inovasi Sains Arsitektur Negeri untuk Kenyamanan Termal Alami Bangunan. Universitas Brawijaya Press.

Rahmawati, A. L., Arifin, L. S., & Dwisusanto, Y. B. (2023). Pendekatan Mimesis Untuk Keberlanjutan Arsitektur Vernakular. Journal of Architecture and Human Experience, 1(1), 23-36.

Samra, B., & Imbardi, I. (2018). Penerapan Aspek Iklim Tropis pada Arsitektur Lokal Rumah Tradisional Melayu Studi Kasus di Desa Lalang Siak Sri Indrapura. Jurnal teknik, 12(1), 68-76.

Toisi, N. H., & Kussoy, J. W. (2012). Pengaruh Luas Bukaan Ventilasi Terhadap Penghawaan Alami Dan Kenyamanan Thermal Pada Rumah Tinggal Hasil Modifikasi Dari Rumah Tradisional Minahasa. Jurnal Arsitektur DASENG, 1(1), 66-73.

Published

2025-02-19